Myers® 4RH and 4RHX Series 4" Non-Clog Wastewater Pumps
Myers® Solids Handling Pumps
Capacity : 450 gpm (28.4 L/s)
Head : 30 ft (39.5 m)
Standard (4RH) and Explosion-Proof (4RHX) Construction
The 4RH and 4RHX (Explosion-proof) Submersible Wastewater Pumps are the right choice when difficult to pump fibrous or stringy solids are to be expected. The 4RH/4RHX series provides smooth, vibration-free operation when operating at heads higher than peak efficiency. For use in municipal lift stations, treatment plants and industrial waste applications. Myers offers a complete line of wastewater pumps, lift-out rail assemblies, controls and accessories to meet your needs.
Advantages By Design
Passes stringy trash, fibrous wastes, slurries and other difficult to pump solids that standard enclosed or semi-open impellers cannot.
Head : 30 ft (39.5 m)
Standard (4RH) and Explosion-Proof (4RHX) Construction
The 4RH and 4RHX (Explosion-proof) Submersible Wastewater Pumps are the right choice when difficult to pump fibrous or stringy solids are to be expected. The 4RH/4RHX series provides smooth, vibration-free operation when operating at heads higher than peak efficiency. For use in municipal lift stations, treatment plants and industrial waste applications. Myers offers a complete line of wastewater pumps, lift-out rail assemblies, controls and accessories to meet your needs.
Advantages By Design
Passes stringy trash, fibrous wastes, slurries and other difficult to pump solids that standard enclosed or semi-open impellers cannot.
- Recessed impeller design has completely open passage in volute.
- Pumping action is by vortex; solids can't get caught in impeller volute.
- Operates without vibration or cavitation over entire performance curve. Operates near shut-off without harming pump.
- Recessed impeller greatly increases bearing life by reducing radial load.
- Oil-filled motor for maximum heat dissipation and constant bearing lubrication.
- Heat sensor thermostats imbedded in windings protect motor from overheat conditions.
- Seal leak probes warn of moisture entry; helps prevent costly motor burn-out.
Unit of Measure
Items |
4RH75M2-03 Standard 4" Non-Clog Wastewater Pumps |
4RH75M2-23 Standard 4" Non-Clog Wastewater Pumps |
4RH75M2-43 Standard 4" Non-Clog Wastewater Pumps |
4RH75M2-53 Standard 4" Non-Clog Wastewater Pumps |
4RH100M2-03 Standard 4" Non-Clog Wastewater Pumps |
|||||
Head | N/A 130 ft39.5 m | |||||||||
Solids Handling | N/A 3 in76 mm | |||||||||
Liquids Handling | N/A Effluent Fiberous Wastewater Raw Unscreened Sewage Storm Water | |||||||||
Intermittent Liquid Temperature | N/A up to 140 ºFup to 60 ºC | |||||||||
Winding Insulation Temperature. (Class H) | N/A 356 ºF180 ºC | |||||||||
Motor Electrical Data |
N/A
3450 RPM 7 1/2-15 HP, 200/230/460/575V 3Ø, 60 Hz 20 HP, 230/460/575V 3Ø, 60 Hz |
|||||||||
Acceptable pH Range | N/A 6 to 9 | |||||||||
Specific Gravity | N/A 0.9 to 1.1 | |||||||||
Viscosity | N/A 28 to 35 SSU | |||||||||
Horizontal Discharge Flanged Centerline | N/A 4 in 125 lb. ANSI 101.6 mm | |||||||||
Motor Housing Material | N/A Cast Iron, Class 30, ASTM A48 | |||||||||
Seal Housing Material | N/A Cast Iron, Class 30, ASTM A48 | |||||||||
Volute Case Material | N/A Cast Iron, Class 30, ASTM A48 | |||||||||
Cord Cap Material | N/A Cast Iron, Class 30, ASTM A48 | |||||||||
Recessed Impeller Material | N/A Ductile Iron, Class 65, ASTM A536 | |||||||||
Power Cord Material | N/A 25 ft. SOOW | |||||||||
Control Cord Material | N/A 25 ft. SOOW | |||||||||
Standard Double Tandem Mechanical Seal Material | N/A Carbon & Ceramic, Type 21 | |||||||||
Optional Double Tandem Mechanical Seal Material | N/A Lower Tungsten, Carbide | |||||||||
Pump Shaft Material | N/A 416 SST | |||||||||
Motor Shaft Material | N/A 416 SST | |||||||||
Fasteners Material | N/A 300 series SST | |||||||||
Speed | N/A 3450 rpm | |||||||||
Power | N/A 7.5 hp | N/A 7.5 hp | N/A 7.5 hp | N/A 7.5 hp | N/A 10 hp | |||||
Voltage | N/A 200 V | N/A 230 V | N/A 460 V | N/A 575 V | N/A 200 V | |||||
Phase | N/A 3 | |||||||||
Frequency | N/A 60 Hz | |||||||||
Start | N/A 128.6 A44.5 kV·A | N/A 111.8 A44.5 kV·A | N/A 55.9 A44.5 kV·A | N/A 44.7 A44.5 kV·A | N/A 192.7 A66.8 kV·A | |||||
Run | N/A 27 A8.1 kW6.3 kV·A | N/A 23.5 A8.1 kW6.3 kV·A | N/A 11.8 A8.1 kW6.4 kV·A | N/A 9.4 A8.1 kW6.3 kV·A | N/A 33.9 A10.2 kW7.9 kV·A | |||||
NEC Code Letter | N/A G | N/A G | N/A G | N/A G | N/A H | |||||
Service Factor | N/A 30.5 A9.5 kW1.2 | N/A 26.5 A9.5 kW1.2 | N/A 13.3 A9.5 kW1.2 | N/A 10.6 A9.5 kW1.2 | N/A 39.7 A11.9 kW1.2 | |||||
Capacity | N/A 450 gpm28.4 L/s | |||||||||
Agency Approvals |
N/A
|
|||||||||
Note | N/A Consult factory for applications outside of these recommendations. | |||||||||
|