Capacity : 315 gpm (19.9 lps)
Head : 100 ft (30.4 m)


Standard (3RH) and Explosion-Proof (3RHX) Construction

Myers 3RH and 3RHX (explosion-proof) submersible wastewater pumps are the right choice when difficult to pump fibrous or stringy solids are to be expected.The 3RH/3RHX series provides smooth, vibration-free operation when operating at heads higher than peek efficiency. For use in commercial lift stations, treatment plants and industrial waste applications. Myers offers a complete line of wastewater pumps, lift-out rail assemblies, controls and accessories to meet your needs.

Advantages By Design
Passes Stringy Trash, Fibrous Wastes, Slurries, and other difficult to pump Solids that standard enclosed or semi-open Impellers can not.
  • Recessed impeller design has completely open passage in volute.
  • Pumping action is by Vortex; solids can not get caught in impeller volute.
  • Operates without vibration or cavitation over entire performance curve. Operates near shut-off without harming pump.
Durable motor will deliver many years of reliable service.
  • Recessed impeller greatly increases bearing life by reducing radial load.
  • Oil-filled motor for maximum heat dissipation and constant bearing lubrication.
  • Heat sensor thermostats imbedded in windings protect motor from overheat conditions.
  • Seal leak probes warn of moisture entry; helps prevent costly motor burnout.
Available with optional F.M. approval for use in class 1, Groups C and D hazardous locations (3RHX only)
Unit of Measure
Items
Myers® 3RH and 3RHX 3 in. Non-Clog Wastewater Pumps

Standard 3" Non-clog Wastewater Pumps

Myers® 3RH and 3RHX 3 in. Non-Clog Wastewater Pumps

Standard 3" Non-clog Wastewater Pumps

Myers® 3RH and 3RHX 3 in. Non-Clog Wastewater Pumps

Standard 3" Non-clog Wastewater Pumps

Myers® 3RH and 3RHX 3 in. Non-Clog Wastewater Pumps

Standard 3" Non-clog Wastewater Pumps

Myers® 3RH and 3RHX 3 in. Non-Clog Wastewater Pumps

Standard 3" Non-clog Wastewater Pumps
Head N/A 100 ft30.4 m
Liquids Handling N/A Effluent Fibrous Wastewater Raw Unscreened Sewage Storm Water
Solids Handling (Diameter) N/A 2 in50.8 mm
Intermittent Liquid Temperature N/A up to 140 ºFup to 60 ºC
Winding Insulation Temperature. (Class F) N/A 311 ºF155 ºC
Motor Electrical Data N/A 3450 RPM 3-5 HP 230V 1Ø, 60 Hz 3-7 1/2 HP 200/230/460/575V, 3Ø, 60 Hz
Acceptable pH Range N/A 6 to 9
Specific Gravity N/A 0.9 to 1.1
Viscosity N/A 28 to 35 SSU
Horizontal Discharge Flanged Centerline N/A 125 lb. ANSI 3 in 76 mm
Motor Housing Material N/A Cast Iron, Class 30, ASTM A48
Seal Housing Material N/A Cast Iron, Class 30, ASTM A48
Volute Case Material N/A Cast Iron, Class 30, ASTM A48
Cord Cap Material N/A Cast Iron, Class 30, ASTM A48
Recessed Impeller Material N/A Ductile Iron, Class 65, ASTM A536
Power Cord Material N/A 25 ft. SOOW
Control Cord Material N/A 25 ft. SOOW
Standard Double Tandem Mechanical Seal Material N/A Carbon & Ceramic, Type 21
Optional Double Tandem Mechanical Seal Material N/A Lower Tungsten, Carbide
Pump Shaft Material N/A 416 SST
Motor Shaft Material N/A 416 SST
Fasteners Material N/A 300 series SST
Power N/A 3 hp
Voltage N/A 200 V N/A 230 V N/A 200 V N/A 230 V N/A 460 V
Phase N/A 1 N/A 1 N/A 3 N/A 3 N/A 3
Frequency N/A 60 Hz
Start N/A 135.0 A27.0 kV·A N/A 75.0 A17.3 kV·A N/A 66 A22.9 kV·A N/A 56.6 A22.5 kV·A N/A 28.3 A22.5 kV·A
Run N/A 17.9 A3.5 kW3.6 kV·A N/A 15.6 A3.5 kW3.6 kV·A N/A 9.9 A3.2 kW2.3 kV·A N/A 8.6 A3.2 kW2.3 kV·A N/A 4.3 A3.2 kW2.3 kV·A
NEC Code Letter N/A L N/A G N/A J N/A J N/A J
Service Factor N/A 23.8 A4.6 kW1.2 N/A 20.7 A4.6 kW1.2 N/A 13.3 A4.3 kW1.2 N/A 11.5 A4.3 kW1.2 N/A 5.8 A4.3 kW1.2
Capacity N/A 315 gpm19.9 lps
Agency Approvals N/A

Note N/A Consult factory for applications outside of these recommendations