Items |
2NFL51-8E Myers® High Head Filtered Effluent Pumps |
2NFL52-8E Myers® High Head Filtered Effluent Pumps |
2NFL72-8E Myers® High Head Filtered Effluent Pumps |
2NFL102-8E Myers® High Head Filtered Effluent Pumps |
2NFL51-12E Myers® High Head Filtered Effluent Pumps |
|||||
Head | N/A 480 ft | |||||||||
Maximum Spherical Solids | N/A 1/16" Diameter | |||||||||
Liquids Handling | N/A Filtered Effluent | |||||||||
Maximum Liquid Temperature | N/A 122 ºF | |||||||||
Motor Electrical Data |
N/A
1/2 HP 115 volts, 1 ph 60 Hz, 3450 RPM 1/2 to 1-1/2 HP, 230 volts, 1 ph 60 Hz, 3450 RPM |
|||||||||
Motor Rating | N/A Continuous Duty | |||||||||
Maximum Motor Starts/24 Hours | N/A 300 | N/A 300 | N/A 300 | N/A 100 | N/A 300 | |||||
Specific Gravity | N/A 0.9 to 1.1 | |||||||||
Viscosity | N/A 28 to 35 SSU | |||||||||
Discharge Size NPT | N/A 1 1/4 in | |||||||||
Pump Shell Material | N/A 300 series SST | |||||||||
Shaft Material | N/A 300 series SST | |||||||||
Coupling material | N/A 300 series SST | |||||||||
Suction Bowl Material | N/A Chemically Resistant Reinforced Nylon | |||||||||
Discharge Bowl Material | N/A Corrosion Resistant Reinforced Polycarbonate | |||||||||
Staging Material | N/A Premier PTFE Reinforced Polyester | |||||||||
Built-in Check Valve | N/A Premier PTFE Reinforced Polyester | |||||||||
Thrust Washers Material | N/A Phenolic | |||||||||
Fasteners Material | N/A 300 series SST | |||||||||
Impeller Wear Ring Material | N/A 300 series SST | |||||||||
Motor Shell Material | N/A SST | |||||||||
End Caps Material | N/A SST | |||||||||
Spline Shaft Material | N/A SST | |||||||||
Electrical Protection | N/A Built-in Overload and Surge Arrestor | |||||||||
Replaceable Motor Lead Wire Assembly |
N/A
14-3 Jacketed Type SJOW-A UL and CSA Recognized |
|||||||||
Windings | N/A Hermetically Sealed | |||||||||
Motor Mounting | N/A NEMA | |||||||||
Overall Pump Height (A) | N/A 24 1/4 in | N/A 24 1/4 in | N/A 26 in | N/A 29 3/4 in | N/A 23 1/4 in | |||||
Motor Height (B) | N/A 9 1/2 in | N/A 9 1/2 in | N/A 10 1/2 in | N/A 11 3/4 in | N/A 9 1/2 in | |||||
Intake Height (C) | N/A 12 in | N/A 12 in | N/A 13 in | N/A 14 1/4 in | N/A 12 in | |||||
Pump End Height (D) | N/A 14 3/4 in | N/A 14 3/4 in | N/A 15 1/2 in | N/A 18 in | N/A 13 3/4 in | |||||
Bypass Orifice Height (E) | N/A 20 3/4 in | N/A 20 3/4 in | N/A 22 1/2 in | N/A 26 1/4 in | N/A 19 3/4 in | |||||
Minimum Liquid Level (M) | N/A 19 1/2 in | N/A 19 1/2 in | N/A 21 in | N/A 23 in | N/A 20 in | |||||
Power | N/A 1/2 hp | N/A 1/2 hp | N/A 3/4 hp | N/A 1 hp | N/A 1/2 hp | |||||
Voltage | N/A 115 V | N/A 230 V | N/A 230 V | N/A 230 V | N/A 115 V | |||||
Maximum Current | N/A 12.0 A | N/A 6.0 A | N/A 8.0 A | N/A 9.8 A | N/A 12.0 A | |||||
Locked Rotor | N/A 64 A | N/A 32 A | N/A 41 A | N/A 49 A | N/A 64 A | |||||
Winding Resistance | N/A 1.0 - 1.3 Ω | N/A 4.2 - 5.2 Ω | N/A 3.0 - 3.6 Ω | N/A 2.2 - 2.7 Ω | N/A 1.0 - 1.3 Ω | |||||
Maximum Fuse/CB | N/A 30 | N/A 15 | N/A 20 | N/A 25 | N/A 30 | |||||
AWG Copper Wire Size1 | N/A 100 ft. @14AWG Copper Wire ft160 ft. @12AWG Copper Wire ft250 ft. @10AWG Copper Wire ft390 ft. @8AWG Copper Wire ft620 ft. @6AWG Copper Wire ft960 ft. @4AWG Copper Wire ft | N/A 1020 ft. @10AWG Copper Wire ft1610 ft. @8AWG Copper Wire ft2510 ft. @6AWG Copper Wire ft3880 ft. @4AWG Copper Wire ft400 ft. @14AWG Copper Wire ft650 ft. @12AWG Copper Wire ft | N/A 1200 ft. @8AWG Copper Wire ft1870 ft. @6AWG Copper Wire ft2890 ft. @4AWG Copper Wire ft300 ft. @14AWG Copper Wire ft480 ft. @12AWG Copper Wire ft760 ft. @10AWG Copper Wire ft | N/A 1540 ft. @6AWG Copper Wire ft2380 ft. @4AWG Copper Wire ft250 ft. @14AWG Copper Wire ft400 ft. @12AWG Copper Wire ft630 ft. @10AWG Copper Wire ft990 ft. @8AWG Copper Wire ft | N/A 100 ft. @14AWG Copper Wire ft160 ft. @12AWG Copper Wire ft250 ft. @10AWG Copper Wire ft390 ft. @8AWG Copper Wire ft620 ft. @6AWG Copper Wire ft960 ft. @4AWG Copper Wire ft | |||||
Capacity | N/A 8 gpm | N/A 8 gpm | N/A 8 gpm | N/A 8 gpm | N/A 12 gpm | |||||
Agency Approvals |
N/A
|
|||||||||
|