Items |
4VH30M6-03 Standard 4" Non-Clog Wastewater Pumps |
4VH30M6-23 Standard 4" Non-Clog Wastewater Pumps |
4VH30M6-43 Standard 4" Non-Clog Wastewater Pumps |
4VH30M6-53 Standard 4" Non-Clog Wastewater Pumps |
4VH50M6-03 Standard 4" Non-Clog Wastewater Pumps |
|||||
Head | N/A 85 ft25.9 m | |||||||||
Solids Handling | N/A 3 in76 mm | |||||||||
Liquids Handling | N/A Effluent Raw Unscreened Sewage Storm Water | |||||||||
Intermittent Liquid Temperature | N/A up to 140 ºFup to 60 ºC | |||||||||
Winding Insulation Temperature. (Class H) | N/A 356 ºF180 ºC | |||||||||
Motor Electrical Data |
N/A
1150 RPM, 3 and 5 HP 200/230/460/575 volts 3Ø, 60 Hz 1750 RPM, 5–20 HP 220/230/460/575 volts 3 Ø, 60 Hz |
|||||||||
Acceptable pH Range | N/A 6 to 9 | |||||||||
Specific Gravity | N/A 0.9 to 1.1 | |||||||||
Viscosity | N/A 28 to 35 SSU | |||||||||
Horizontal Discharge Flanged Centerline | N/A 4 in. 125 lb. ANSI 101.6 mm | |||||||||
Motor Housing Material | N/A Cast Iron, Class 30, ASTM A48 | |||||||||
Seal Housing Material | N/A Cast Iron, Class 30, ASTM A48 | |||||||||
Volute Case Material | N/A Cast Iron, Class 30, ASTM A48 | |||||||||
Cord Cap Material | N/A Cast Iron, Class 30, ASTM A48 | |||||||||
Enclosed 2-Vane Impeller Material | N/A Ductile Iron, Class 65, ASTM A536 | |||||||||
Power Cord Material | N/A 25 ft. SOOW | |||||||||
Control Cord Material | N/A 25 ft. SOOW | |||||||||
Standard Double Tandem Mechanical Seal Material | N/A Carbon & Ceramic, Type 21 | |||||||||
Optional Double Tandem Mechanical Seal Material | N/A Lower Tungsten, Carbide | |||||||||
Pump Shaft Material | N/A 416 SST | |||||||||
Motor Shaft Material | N/A 416 SST | |||||||||
Fasteners Material | N/A 300 series SST | |||||||||
Volute Wear Ring Material | N/A Brass | |||||||||
Speed | N/A 1150 rpm | |||||||||
Power | N/A 3 hp | N/A 3 hp | N/A 3 hp | N/A 3 hp | N/A 5 hp | |||||
Voltage | N/A 200 V | N/A 230 V | N/A 460 V | N/A 575 V | N/A 200 V | |||||
Phase | N/A 3 | |||||||||
Frequency | N/A 60 Hz | |||||||||
Start | N/A 77.0 A26.7 kV·A | N/A 67.0 A26.7 kV·A | N/A 33 A26.7 kV·A | N/A 27 A26.7 kV·A | N/A 115 A39.8 kV·A | |||||
Run | N/A 15.9 A3.3 kW5.5 kV·A | N/A 13.8 A3.3 kW5.5 kV·A | N/A 7 A3.3 kW5.5 kV·A | N/A 5.5 A3.3 kW5.5 kV·A | N/A 24 A5.4 kW8.3 kV·A | |||||
NEC Code Letter | N/A K | N/A K | N/A K | N/A K | N/A J | |||||
Service Factor | N/A 19 A4.3 kW1.2 | N/A 16.6 A4.3 kW1.2 | N/A 8.3 A4.3 kW1.2 | N/A 6.6 A4.3 kW1.2 | N/A 29.0 A6.9 kW1.2 | |||||
Capacity | N/A 900 gpm56.7 L/s | |||||||||
Agency Approvals |
N/A
|
|||||||||
Note | N/A Consult factory for applications outside of these recommendations. | |||||||||
|