Items |
4WHV30M4-21 Myers® 4WHV and V4WHV Series 4" Non-Clog Wastewater Pumps |
4WHV30M4-03 Myers® 4WHV and V4WHV Series 4" Non-Clog Wastewater Pumps |
4WHV30M4-23 Myers® 4WHV and V4WHV Series 4" Non-Clog Wastewater Pumps |
4WHV30M4-43 Myers® 4WHV and V4WHV Series 4" Non-Clog Wastewater Pumps |
4WHV30M4-53 Myers® 4WHV and V4WHV Series 4" Non-Clog Wastewater Pumps |
|||||
Head | N/A 59 ft17.9 m | |||||||||
Solids Handling (Diameter) | N/A 3 in76 mm | |||||||||
Liquids Handling | N/A Effluent Raw Unscreened Sewage Storm Water | |||||||||
Intermittent Liquid Temperature | N/A up to 140 ºFup to 60 ºC | |||||||||
Winding Insulation Temperature. (Class F) | N/A 311 ºF155 ºC | |||||||||
Motor Electrical Data1 | N/A 1750 RPM 3-10 HP, 200/230/460/575V,3Ø, 60 Hz 3-5 HP, 230V, 1Ø, 60 Hz | |||||||||
Acceptable pH Range | N/A 6 to 9 | |||||||||
Specific Gravity | N/A 0.9 to 1.1 | |||||||||
Viscosity | N/A 28 to 35 SSU | |||||||||
Discharge, Flanged Centerline. (Horizontal or Vertical) | N/A 4 in101.6 mm | |||||||||
Minimum Sump Diameter (Duplex) | N/A 60 in105 m | |||||||||
Motor Housing Material | N/A Cast Iron, Class 30, ASTM A48 | |||||||||
Seal Housing Material | N/A Cast Iron, Class 30, ASTM A48 | |||||||||
Volute Case Material | N/A Cast Iron, Class 30, ASTM A48 | |||||||||
Cord Cap Material | N/A Cast Iron, Class 30, ASTM A48 | |||||||||
Enclosed 2-Vane Impeller Material | N/A Ductile Iron, Class 65, ASTM A536 | |||||||||
Power Cord Material | N/A 20 ft. SOOW | |||||||||
Control Cord Material | N/A 20 ft.SOOW | |||||||||
Standard Double Tandem Mechanical Seal Material | N/A Carbon & Ceramic, Type 21 | |||||||||
Optional Double Tandem Mechanical Seal Material | N/A Tungsten, Carbide | |||||||||
Pump Shaft Material | N/A 416 SST | |||||||||
Motor Shaft Material | N/A 416 SST | |||||||||
Fasteners Material | N/A 300 series SST | |||||||||
Volute Wear Ring Material | N/A Brass | |||||||||
Power | N/A 3 hp | |||||||||
Voltage | N/A 230 V | N/A 200 V | N/A 230 V | N/A 460 V | N/A 575 V | |||||
Phase | N/A 1 | N/A 3 | N/A 3 | N/A 3 | N/A 3 | |||||
Frequency | N/A 60 Hz | |||||||||
Start | N/A 101 A23.2 kV·A | N/A 66.7 A23.0 kV·A | N/A 58 A23.0 kV·A | N/A 29 A23.0 kV·A | N/A 21.3 A23.0 kV·A | |||||
Run | N/A 17.5 A2.1 kW4.0 kV·A | N/A 15.0 A3.5 kW5.0 kV·A | N/A 12.0 A3.5 kW5.0 kV·A | N/A 6 A3.5 kW5.0 kV·A | N/A 5 A3.5 kW5.0 kV·A | |||||
NEC Code Letter | N/A J | N/A G | N/A G | N/A G | N/A G | |||||
Service Factor | N/A 21 A2.5 kW1.2 | N/A 18 A4.3 kW1.2 | N/A 14.4 A4.3 kW1.2 | N/A 7.2 A4.3 kW1.2 | N/A 6 A4.3 kW1.2 | |||||
Capacity | N/A 720 gpm45.5 lps | |||||||||
Agency Approvals |
N/A
|
|||||||||